Digital thermometer
National Service Hotline:
13116702695National Service Hotline:
13116702695General description
This series of temperature transmitters are installed on site with electrical isolation.
Receiving thermal resistance, thermocouple, resistance, millivolts
Signal input and can be converted to 4-20ma signal output.
The transmitter can be configured through the button on the instrument panel, or through the button
Connect to PC configuration via 1 USB modem.
Functional specification
The input
Thermal resistance/resistance
LD heat resistance
Pt100/Pt1000 conforms to IEC60751 standard.
Resistance value
0... 400
0... 4000
Connect the cable
Maximum sensor line resistance (Rw) per circuit; 50.
Meet the requirements of NE89 (January 2009).
Two - wire circuit: up to 100 line resistance can be compensated.
Sensor fault signal
RTD: short circuit and circuit break
Linear resistance measurement: circuit break
Thermocouple/voltage
Degree,
K,N,E,J,T,B,R,S accord with IEC60584 standard.
Voltage value
- 125... 125 mv
Connect the cable
Maximum sensor line resistance (RW) per circuit: 1.5K, total resistance 3K
Input resistance
10 m or more
Built-in temperature compensator
Pt100, IEC 60751 C1. B
Sensor fault signal
Thermocouple: disconnect
Linear voltage measurement: circuit break
The output
Transmission characteristics
Linear output with temperature, resistance and voltage.
The output signal
4-20 ma
Fault current signal
Power supply (support reverse polarity protection)
Two-wire system, power line equals signal line
The power supply voltage
The operating voltage is 12-35v.
The installation
The transmitter can be mounted directly to the sensor
Remote installation can also be achieved by mounting bracket
Electrical connections 2 m20x1.5 outlets or 2 npt1/2 outlets (via adapter)
Protection grade IP66 and IP67
The weight of the 1 kg
The basic information
Electrical edge
1KV AC (input/output)
Input filter
50/60 hz
Damping time
1-32s can be set, the default is 1S
The refresh rate
0.5 S or less
Operating temperature
40 ℃ -- 85 ℃
When the temperature is lower than -30℃, the LCD may not display properly, and the display update rate will decrease.
Transport/storage temperature
- 50 ℃ to 85 ℃
Maximum permissible humidity
5-100% RH
Physical specifications
Overall dimensions
See section 6 "dimensions"
Junction box material
Die casting low copper aluminum
color
Blue RAL9002
Cold end compensation accuracy
Pt100 DIN IEC 60751 c1. B, 0.3℃ (thermocouple only)
Environmental temperature effect
See table 1 on page 2
The power influence
The power impact per volt is 0.005%
The stability of
0.1 or 0.1% (whichever is higher) of the temperature transmitter reading for 12 months
Vibration resistance
During work and transportation, the displacement is 10-60hz 0.21mm
60-2000 hz 3 g
Electromagnetic compatibility
Meet the level requirements of IEC61326(2006) and NAMUR NE21
Table 1 influence of measurement accuracy and ambient
Note:
1) the measurement accuracy is subject to the large value of fixed value and range value:
2) the influence caused by the change of ambient temperature is subject to the large value of the variable value and the range value.
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
Address: 1510, Building B, Yigou Building, No.168 Huayuangang Street, Gongshu District, Hangzhou, Zhejiang Province