Thermal resistance
National Service Hotline:
13116702695National Service Hotline:
13116702695The working principle of
Assemble thermal resistance armoring thermal resistance
Thermal resistance is used to measure the temperature of a substance by the characteristic that its resistance changes with the change of temperature. When the resistance value changes, the operating instrument displays the temperature value corresponding to the resistance value.
Flameproof thermal resistance
Based on the principle of material gap explosion proof, the design of junction box and other parts with sufficient strength will produce sparks and arc and dangerous temperature of the components are in the junction box cavity, when the explosion occurred in the box, through the joint surface gap ,The flamebox is cooled so that the flame and temperature after the explosion cannot be transmitted to the outside of the box.
Overview of thermal resistance performance
Product implementation standard: IEC751 GB/ t8622-1997
Temperature range and tolerance
Insulation resistance at room temperature
The thermal resistance of armor is at the ambient temperature of 15-35℃, the relative temperature is not more than 80%, and the experimental voltage is 10-100 - v (dc), and outer casing of the insulation resistance between the electrodes Ω 1000 m or higher
Resistance wire diameter material and material
Temperature range and tolerance
Explosion-proof thermal resistance
Measurement range and tolerance
Integrated explosion-proof thermal resistance
The working principle of
The thermal resistance of explosion proof USES the principle of gap explosion proof, when the explosion happens in the cavity, it can shut off and cool down through the gap of the joint surface, so that the full temperature of the flame after the explosion cannot be transmitted outside the cavity, so as to carry out explosion proof.
The thermoelectric potential resistance generated by the thermal resistance generates unbalanced signal through the bridge of the temperature transmitter, which is amplified and converted into 4~20mA direct current signal to the working instrument, which displays the corresponding temperature value.
Product execution standard
IEC751
JB/T5518-1991
Measurement range and tolerance
Working environment
Precision grade
Accuracy class of temperature transmitter: 0.1; 0.2; 0.5
Precision level of display: 2.5 level of analog indicator; Digital display level 1.0
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
Address: 1510, Building B, Yigou Building, No.168 Huayuangang Street, Gongshu District, Hangzhou, Zhejiang Province