Intelligent flow totalization controller

Intelligent flow totalization controllerThe intelligent flow totalization controller uses advanced microprocessor for intelligent control, which is suitable for flow detection and integration control

National Service Hotline:

13116702695

Intelligent flow totalization controller


The intelligent flow totalization controller uses advanced microprocessor for intelligent control, which is suitable for flow detection and integration control of various liquids, general gases, steam, natural gas, etc. Using the look-up table method for density compensation, it can automatically perform high-precision integration control on superheated steam and saturated steam. Built-in multiple flow calculation formulas, which can adapt to various flow measurement occasions.


With a variety of signal input functions, it can be equipped with various pressure / differential pressure and frequency flow sensors (such as orifice plates, vortex streets, turbines, etc.), and the above input signals can be realized by simply selecting the instrument menu Easy switching between them improves the versatility and reliability of the instrument. With a variety of compensation methods (such as temperature compensation, pressure compensation, temperature compensation + pressure compensation, etc.) to choose from.

     

Wide measurement display range, it can display the instantaneous flow value, temperature compensation value, pressure compensation value, flow rate, volume (or differential pressure / frequency) value of the whole five digits, and the cumulative flow value of the whole thirteen digits (0-9,999,999,999,999) High accuracy, the cumulative value can be accurate to the last three digits of the decimal point (0.001). You can also set the internal parameters to make the maximum accumulated value reach 99,999,999,999.99 × 100. With a measurement status indicator display, it is convenient to observe the measurement object, and the input / output circuits are optically isolated.


Product Details Mathematical Model


· See meter operation manual


Measurement accuracy · Measurement display accuracy: ± 0.5% FS ± 1


                     Frequency conversion accuracy: ± 1 pulse (LMS) is generally better than 0.2%


Display mode · High-brightness LED digital display · Full Chinese large screen (with backlight) LCD (liquid crystal) display


                     · LED working status display · Current date and time display


                     Five-digit (0 to 99999) instantaneous flow value display11-digit (0 to 99,999,999,999) cumulative flow value display


                     · Five-digit (0 ~ 99999) pressure compensation value display · Five-digit (-19999 ~ 99999) temperature compensation value display


                     Five-digit (0 to 99999) flow (or differential pressure / frequency) value display


Control methodSelectable upper limit, lower limit or upper limit, lower limit control, with normally open / normally closed output


Control setpointFreely set the control setpoint and hysteresis in the full range


Quantitative control · Selectable flow quantification to control, LED output indication


                      · Select flow quantitative process control, LED output indication


Compensation methodAuto temperature, pressure, temperature + pressure compensation


This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.

Instrument dimensions and opening dimensions


图片关键词

Intelligent flow totalizer controller


图片关键词

Note: Modbus protocol is recommended and WP protocol is phased out.

★ note: 1. See the attached wiring diagram for the external start, stop and zero clearing functions.

2. L802, l803 and l804 series can switch each other by setting the secondary parameters of the instrument. When measuring saturated steam, only one of pressure or temperature compensation can be selected.

3. If the user selects the specific curve compensation input (look-up table method), please provide relevant technical parameters or density table when ordering.

Model selection examples: ld-l802-02-fag-hl-t; ld-ls802-71-aag-hl-w;

LD-LCS802-01-ANG-HL-P-W; LD-LC802-01-ANG-HL-P-T


图片关键词

图片关键词

000.jpg



This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.

This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.