363L Series Monocrystalline Silicon Flange Mounted Transmitter
National Service Hotline:
13116702695National Service Hotline:
13116702695Performance
The overall performance is based on the combined error of reference accuracy, ambient temperature influence, and range static pressure influence.
Accuracy index
± 0.075% FS range (conventional)
Specific performance indicators
(Zero-based range, reference conditions, silicone oil-filled liquid, 316 stainless steel isolation diaphragm, 4-20mA analog output, digital trim value equal to range setpoint value.)
Accuracy
(Reference accuracy includes hysteresis, terminal-based linearity, setting capability, and repeatability)
± 0.075% of range
If the range is less than X
± [0.025 + 0.05 (X / range)]%
X value
Damping time constant
The total damping time constant is equal to the sum of the damping time constants of the amplifier components and the capsule. The damping time constant of the amplifier component is adjustable in the range of 0 to 100 seconds.
Capsule (silicone oil)
Time constant (second) (time constant can be set according to the actual situation on site, 1S is recommended)
Influence of installation position
The change in the installation position parallel to the diaphragm surface will not cause zero drift. If the installation position and the diaphragm surface change by more than 90 °, the zero drift in the range of 0.4KPa can be corrected by zero adjustment without affecting the range.
Power impact
Less than ± 0.005% of range / volt
Functional indicators
Range and sensor limits
Table 1.363L range and sensor limit values
Zero and span adjustment requirements
· Zero and span values can be set arbitrarily within the span limits indicated in Table 1.
• The range must be greater than or equal to the minimum range indicated in Table 1.
Application occasion
Measurement of liquid, gas and steam
Output
The second line is 4-20mA, user-selectable linear. The digital process variable is superimposed on the 4-20mA signal and is suitable for any host using the HART protocol.
power supply
Requires external power. The standard transmitter (4-20mA) operates at 14.5-45V dc with no load.
Loop load limit
The maximum loop resistance is determined by the external power supply voltage and the relationship is as follows:
Note: The supply voltage range of the transmitter with backlight display is 14.5 ~ 45V
Intrinsically safe transmitter power supply voltage range is 14.5 ~ 28V
The working voltage during HART communication should be greater than 17.5V
Static pressure limit and maximum overpressure
For type 363L limit value is 0psia to flange rating or sensor
The smaller of the rated pressure values.
Table 2. 363L flange pressure ratings
Failure mode
Output code
If the sensor or microprocessor malfunctions, the transmitter will drive a high or low alarm signal to remind the user. The alarm output value depends on the factory configuration of the transmitter:
Linear output: 3.8 <I <20.8
C4: I = 20.8mA high fault
CN: I = 3.8mA low fault
Temperature limit
surroundings
-20 ℃ ~ + 70 ℃ (general)
-40 ℃ ~ + 85 ℃ (highest)
Storage
-46 ℃ ~ 110 ℃
With meter head: -40 ℃ ~ 85 ℃
process
At or above atmospheric pressure, see the table below
Table 3.363L process temperature limits
Humidity limit
0-100% relative humidity
Start Time
Transmitter meets performance indicators within 2 seconds of power up
Mechanical performance index
Electrical Interface
ANSI (American Standard) NPT1 / 2 (F) internal thread
ISO (national standard) M20 × 1.5 internal thread
Process interface
High pressure side: flange size (implement national and chemical standards)
NP series: DN25 DN40 DN50 DN80 DN100
PN2.5 PN6 PN10 PN16 PN25 PN40
Class series: 1 inch 1½ inch 2 inch, 3 inch, 4 inch
150lb, 300lb
Low-pressure side: 1 / 4-18NPT cone pipe internal thread
T-shaped connector: M20 × 1.5 external thread
Waist-shaped connector: 1 / 2-14NPT cone pipe internal thread
1 / 2-14NPT impulse transition head and rear welded impulse pipe
Process wetted parts
Process isolation diaphragm: 316L stainless steel, Hastelloy C (no option for insert tube), tantalum (no option for insert tube).
Drain / Exhaust Valve
316 stainless steel
Process flanges and fittings
316 stainless steel
363L process wetted parts
Flange type process interface (high side of transmitter)
Process diaphragm including process gasket contact surface
316L stainless steel, Hastelloy C or tantalum
Stick out
316 stainless steel
Mounting flange
Carbon steel galvanized or stainless steel
Low-voltage side process connection (low-voltage side of transformer)
Isolation diaphragm
316L stainless steel
Low side flange and joint
316 stainless steel
Non-wetted parts
Electronic housing Coating O-ring on cover
Die-cast aluminum IP65 spray-coated nitrile rubber
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
This information is for reference only. In order to continuously improve product performance, all pictures and performance parameters on this website are subject to change without notice, please forgive me! The company reserves the right of final interpretation of all technical parameters and pictures.
Address: 1510, Building B, Yigou Building, No.168 Huayuangang Street, Gongshu District, Hangzhou, Zhejiang Province